PAPR

Product Feature

Economical Efficiency

More than 40% cost savings compared to other competitors’ products

Purpose

The respirator equipment helps protect the user(head and face) from certain contaminants, such as welding fume, harmful dust, harmful odors, organic/inorganic chemistry, acids, ammonia and respiratory infectious pathogen. The powered air purifying respirator produces clean and fresh air after purifying the contaminated external air by using particulate filter or gas filter.

Safety

Excellent chemical-resistant materials applied to the hood fabric and the face shied to completely protect eyes and face.
In case of danger (filter blockage, low battery power), the user is alerted with alarm sound and blower vibration.

Comfortable wearing

Applying ergonomically designed new suspenders belt improved the disadvantages and discomfort of the existing waist belt. It distributes the weight of blower and provides maximum comfort for long-term wear. It improves work efficiency.

Wide view

The face shield of hood has high transparency and provides a wide view. It reduce eye fatigue during work.

Ultralight product

minimized the weight 1.15kg (excluded hood & hose)

Compatibility with various hoods

Various hoods are available depends on working condition.

Product Parts

Blower

• Ultralight PAPR among other PAPR products

• Price competitiveness compared to competitors’ products.

• A high flow rate.

• Compatible of Dust and gas filters

• Danger warning system – alarm sound, LED display

• Easy flow control – one touch system Display information on LCD panel

Blower

Filter Part

• Approved by NIOSH 42 CFR 84

• 99.97% Filtration of Airborne Particles.

Filter Part

Certified filter that purifies dust and other contaminants floating in the air.

Vinyl Cover

Hose, suspenders anti-pollution vinyl cover

Hood

The excellent transparency of face shied makes it easy to view. It has excellent cold resistance and chemical resistance.
Hood

Hose

The polyurethane hose is safe from the danger caused by hose twisting during work and has excellent resistance to high flow rates.
Hose

LCD Display(MAIN) and KEY Control

1) MAIN LCD Operation

MAIN LCD Operation

2) Filter/Hose blockage

Normal

Filter/Hose blockage Normal

Warning

Filter/Hose blockage Normal

Danger

Filter/Hose blockage Normal

LCD Display(INFO) and KEY control

1 Step

Push INFO KEY to enter INFO MODE at MAIN MODE
Information Entry Step 1

2 Step

Use ARROW KEY to change MODE after INFO MODE entry
Information_Entry 2

3 Step

Push and hold INFO KEY to return to INFO MODE
Information_Entry 3

INFO MODE Order

1. Accumulated Using Hours of Filter

INFO MODE Order 1

2. Current Time

INFO MODE Order 2

3. External LED Setting

INFO MODE Order 3

4. LCD Contrast Control

INFO MODE Order 4

5. LCD Display Reversal

INFO MODE Order 5

INFO Function

1) Accumulated Using Hours of Filter

1 Step

Push INFO KEY to check the using Hours of filter at MAIN MODE
INFO_Function_01_Step01

2 Step

Push INFO KEY(Short) to show CLEAR BOX for initialization of the using hours of filter
INFO_Function_01_Step02
Push and hold INFO KEY to return to MAIN MODE

3 Step

After CLEAR BOX showed up, push POWER KEY(Short) to initialize the using hours of filter
INFO_Function_01_Step03
Push and hold INFO KEY to return to MAIN MODE

2) Adjust Current Time

1 Step

Push ARROW KEY to enter CLOCK SET MODE from the using hours of filter screen, push INFO KEY again and HOUR is blinking
INFO_Function_02_Step01
Push and hold INFO KEY to return to MAIN MODE

2 Step

While HOUR is blinking, adjust the HOUR using ARROW KEY
INFO_Function_02_Step02

3 Step

Push INFO KEY again, MINUTE is blinking Same way with HOUR adjust using ARROW KEY
INFO_Function_02_Step03

4 Step

After complete to adjust, push POWER KEY(short) to save the value
INFO_Function_02_Step04
Push and hold POWER KEY to POWER OFF

3) External LED ON/OFF

1 Step

Push ARROW KEY to enter External LED ON/OFF MODE from CLOCK SET MODE screen
INFO_Function_03_Step01
Push and hold INFO KEY to return to MAIN MODE

2 Step

Push INFO KEY to move External LED OFF BOX
INFO_Function_03_Step02

3 Step

After complete to adjust, push POWER KEY(short) to save the value
INFO_Function_03_Step03
Push and hold POWER KEY to POWER OFF

4) LCD Contrast Control

1 Step

Push ARROW KEY to enter LCD Contrast Control MODE from External LED ON/OFF MODE Screen
INFO_Function_04_Step01
Push and hold INFO KEY to return to MAIN MODE

2 Step

Push INFO KEY to adjust LCD Contrast
INFO_Function_04_Step02

3 Step

After complete to adjust, push POWER KEY(short) to save the value
INFO_Function_04_Step03
Push and hold POWER KEY to POWER OFF

5) LCD Display Reversal

1 Step

Push ARROW KEY to enter LCD Display Reversal MODE from LCD Contrast Control MODE
INFO_Function_05_Step01
Push and hold INFO KEY to return to MAIN MODE

2 Step

Push INFO KEY to move REV(Reversal) BOX for the display reversal
INFO_Function_05_Step02

3 Step

After complete to adjust, push POWER KEY(short) to save the value
INFO_Function_05_Step03
Push and hold POWER KEY to POWER OFF